Model Number : ST502

Pipe Size : DN25-DN5000

MOQ : 1

Velocity Range : 0.03 ~±40ft/s (0.01~±12m/s)

Brand Name : Flo-Instru

Output : 4-20mA, OCT pulse output, relay output, RS-232 / RS-485, RTD temp. input

Delivery Time : 3-5 working days

Payment Terms : T/T

Repeatability : 0.15%

Packaging Details : Conventional Packaging

Certification : CE; ISO9001

Transducers temperature : -40℉ ~ +140℉ (-40℃~+60℃)

Place of Origin : Shenzhen

Power Supply : 24V DC

Contact Now

ST502 Clamp-On Ultrasonic Flow Meter for District Heating
Product Overview

ST502 Ultrasonic Flowmeter utilizes transit-time methods to measure liquid flow in industrial systems, delivering high-accuracy flow data through clamp-on transducers that never contact the fluid.

Key Features
  • Measures actual flow and total consumption of various liquids
  • CNC machined process with magnetic open cover technology
  • Adaptive signal processing algorithms for challenging flow conditions
  • Clear LCD display with alarm function and easy operation
  • Bidirectional flow measurement using transit-time ultrasonic technology
  • Built-in 2G SD card for historical flow data analysis
  • Simple menu system for fast configuration
Measurement Principle - TVT Technology

TVT (Transit-Time Vortex) technology combines transit-time ultrasonics with vortex shedding phenomenon, delivering unparalleled accuracy and versatility in ultrasonic flow measurement.

ST502 clamp on ultrasonic flow meter for district heating

The device uses ultrasonic transducers installed on the pipe exterior. One transducer sends pulses downstream with flow, while the other sends upstream against flow. The time difference between signals is proportional to flow velocity.

Performance Specifications
Velocity Range 0.03 ~ ±40ft/s (0.01 ~ ±12m/s)
Accuracy ±0.5%
Pipe Size 1"~200" (25mm~5000mm)
Repeatability 0.15% of measured value
Linearity ±1.0%
Fluid Compatibility Water, Sea water, Oil, Alcohol...
Pipe Material PVC, stainless steel, carbon steel, copper...
Function Specifications
Communication ModBus RS485
Analog Output 4~20mA, max load 750Ω
Pulse Output 0~9999Hz, OCT
Relay Output max 1Hz (1A@125V AC or 2A@30V DC)
Power Supply 24V DC/1A max
Temperature Range -40°F~140°F (-40°C~60°C)
Humidity Up to 99% RH, non-condensing
Product Dimensions
Transmitter
ST502 clamp on ultrasonic flow meter for district heating
Normal Transducer
ST502 clamp on ultrasonic flow meter for district heating
High-temperature Transducer
ST502 clamp on ultrasonic flow meter for district heating
Ultra High-temperature Transducer
ST502 clamp on ultrasonic flow meter for district heating
Product Display
ST502 clamp on ultrasonic flow meter for district heating
Communication & Output Functions

The ST502 offers multiple communication and output options for seamless integration into industrial control systems, enabling real-time data acquisition and remote monitoring.

ST502 clamp on ultrasonic flow meter for district heating ST502 clamp on ultrasonic flow meter for district heating
Output Capabilities Summary
Output Type Function Application Examples
RS485 (Modbus) Digital communication Remote monitoring, SCADA, system integration
4-20mA Analog input/output PLC input, process feedback, DCS systems
OCT Pulse Flow totalization output Batch controllers, energy meters, flow loggers
Relay Alarm/control output Trigger alarms, control valves/pumps, flow safety protection
Wiring Diagram
ST502 clamp on ultrasonic flow meter for district heating
Installation Methods
V Method

Standard method providing accurate readings for pipe diameters 25mm to 400mm (1"~16"). Requires proper transducer installation at pipe centerline with equal spacing.

ST502 clamp on ultrasonic flow meter for district heating
Z Method

Utilizes directly transmitted signals with less attenuation. Suitable for pipe diameters 100mm to 3000mm (4"~120").

ST502 clamp on ultrasonic flow meter for district heating
N Method

Sound waves traverse fluid twice and bounce three times off pipe walls. Suitable for small pipe diameters, improving accuracy by extending transit distance.

ST502 clamp on ultrasonic flow meter for district heating
W Method

Sound waves traverse fluid four times and bounce four times off pipe walls. Suitable for very small pipes (diameters less than 50mm, 2").

ST502 clamp on ultrasonic flow meter for district heating

Product Tags:

DN25-DN5000 Pipe Size Ultrasonic Flow Meter

      

24V DC Power Supply Clamp-On Flow Meter

      

0.15% Repeatability ST502 Flow Meter

      
Quality ST502 clamp on ultrasonic flow meter for district heating for sale

ST502 clamp on ultrasonic flow meter for district heating Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Flo-Instruments Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)